Flyback is the most widely used topology in low- and mid-power switch-mode power supplies. Turning a 100W / 12V adapter spec into a producible transformer involves trade-offs at every step—what turns ratio to pick, how to set the inductance, whether the turns will saturate, how to choose the wire gauge, and whether the temperature rise stays manageable. This article walks through each calculation with its basis; all data are sourced and can serve as an engineering checklist.
| Parameter | Value | Note |
|---|---|---|
| Input voltage | 85–265 VAC (universal) | After rectifier VDC_min≈100 V, VDC_max≈375 V |
| Output | 12 V / 8.33 A (100 W) | Schottky rectifier, Vf=0.7 V |
| Topology | Flyback, DCM | Discontinuous conduction, primary current triangle bottoms at zero |
| Switching freq. | 100 kHz | Classic adapter range |
| Target efficiency | >90% | Whole unit |
| Max duty | Dmax=0.45 (limit) | Margin kept; actual lands at 0.41 |
We use TDK PC95EER28-Z (IEC 62317 outline, PC95 material). PC95 keeps 410 mT saturation at 100°C with lower volumetric loss than PC40, making it a sound choice for efficient adapters. Its official key parameters:
| Parameter | Symbol | Value |
|---|---|---|
| Effective area | Ae | 82.1 mm² (=0.821 cm²) |
| Effective path length | le | 64 mm |
| Effective volume | Ve | 5250 mm³ (=5.25 cm³) |
| Ungapped AL | AL | 4000 ±25% nH/N² |
| Saturation (100°C) | Bs | 410 mT (H=1194 A/m) |
| Vol. loss (100kHz, 200mT, 100°C) | Pcv | 280 kW/m³ |
| Weight | — | 28 g |
All subsequent turns, saturation and core-loss calculations use this official parameter set.
DCM flyback turns-ratio formula (boundary at min input, max duty):
n = Np/Ns = Vin_min·Dmax / [(1−Dmax)·(Vo+Vf)] = 100×0.45 / (0.55×12.7) = 6.44
Use standardized n=6.5; reflected voltage Vor=n·(Vo+Vf)=6.5×12.7≈82.6 V. Peak switch voltage Vds_max=Vin_max+Vor=375+82.6≈457.6 V, so pick a 650 V MOSFET (e.g. FCP11N60) for margin.
In DCM the primary current is a triangle bottoming at zero, so peak equals ΔI. From power balance:
Note: in the DCM Lp formula, ΔI is the peak current (not half the ripple).
By Faraday's law (design swing ΔB=0.25 T=2500 Gauss):
Np = Vin_min·Dmax·10⁸ / (fs·Ae(cm²)·ΔB(Gauss)) = 100×0.45×10⁸ / (100000×0.821×2500) = 22.0 turns, take Np=22
Secondary Ns=Np/n=22/6.5=3.38, round up Ns=4, so actual ratio nact=22/4=5.5. Re-check max duty:
Dmax_act = n·(Vo+Vf) / [Vin_min+n·(Vo+Vf)] = 69.85 / (100+69.85) = 0.411 < 0.45 ✓
Re-check peak flux density (true Ae=0.821, Dmax_act=0.411):
Bmax = Vin_min·Dmax_act·10⁸ / (Np·Ae·fs) = 100×0.411×10⁸ / (22×0.821×100000) = 2278 Gauss = 0.228 T
0.228 T is well below the 0.25 T design swing and PC95 saturation of 410 mT@100°C—ample margin. Auxiliary winding for Vcc≈15 V: Naux=Ns·(Vaux+Vf)/(Vo+Vf)=4×15.7/12.7≈4.94, take 5 turns (gives Vcc≈15.1 V).
Current density J=4.5 A/mm². Primary RMS Ip_rms=Ip_pk·√(Dmax/3)=4.94×√(0.411/3)=1.83 A → copper area 0.407 mm²; secondary Is_pk=n·Ip_pk=5.5×4.94=27.2 A, Is_rms=27.2×√((1−0.411)/3)=12.05 A → copper area 2.68 mm².
Winding uses the standard two-layer primary (11 turns each) split layout (helps lower leakage and spread evenly): primary layer 1 → insulation → primary layer 2 → insulation → aux → insulation → secondary. At least 3 layers of 0.05 mm polyester tape + margin tape between primary and secondary.
Copper loss: primary MLT≈50 mm, 22 turns → 1.1 m, 4 parallel → Rp≈0.066 Ω (with AC factor Fr≈1.5), Pcu_p=1.83²×0.066×1.5≈0.33 W; secondary 4 turns → 0.2 m, 14 parallel → Rs≈0.0017 Ω (Fr≈1.3), Pcu_s=12.05²×0.0017×1.3≈0.32 W. Total copper ≈ 0.65 W.
Core loss: per TDK PC95, Pcv=280 kW/m³ at 100kHz/200mT/100°C; actual swing ΔB=0.228 T, extrapolated from 200 mT by Steinmetz (Pcv∝B^α, α≈2.5–2.7) gives Pcv≈395 kW/m³. Then:
Pfe = Pcv·Ve = 395×10³ × 5.25×10⁻⁶ ≈ 2.07 W (Ve=5250 mm³)
Total magnetic loss Ptrans≈0.65+2.07≈2.7 W.
Semiconductor losses: switch ≈4 W, rectifier ≈2 W, other ≈1 W, plus magnetics 2.7 W → total loss ≈ 9.7 W, η=100/(100+9.7)≈91.1%, meeting the >90% target.
Temperature rise: use the surface thermal-resistance method for a sound estimate. ER28 magnetics in natural convection have ≈45–55 °C/W; 2.7 W loss implies ≈55–65 °C rise; with bobbin, pins and PCB copper helping, the core rise at full load typically lands 40–60 °C (core ≈80–100 °C), still within PC95 limits. The exact value must be measured; if too hot, drop to 65 kHz or move to PQ26/RM10 for more surface.
Primary-secondary isolation is reinforced insulation. Per IEC 62368-1, at 250 V working voltage, pollution degree 2, material group IIIa, reinforced-insulation creepage requires ≥6.4 mm. In practice use triple-insulated wire (TIW) or margin tape + ≥3 layers of 0.05 mm tape between pri/sec, and form a margin so the creepage path ≥6.4 mm. Meets EN 61558 / IEC 62368 isolation.
Turning each step above into a physical part, the real gate is manufacturing: ① air-gap consistency—a 0.3 mm center-pole grind; grind tolerance decides whether Lp lands in 90 µH±10%, needing CNC gap grinding and per-unit inductance test; ② winding uniformity—layered primary and parallel strands affect leakage (target <3% Lp, i.e. <2.7 µH) and AC loss; ③ insulation reliability—3000 VAC/60 s hi-pot, creepage ≥6.4 mm, via margin and TIW; ④ thermal validation—prototype at full load 2 h, core <110 °C, winding <120 °C.
We run transformer and inductor lines in Shenzhen, Hunan and Vietnam, focused on custom high-frequency transformers, differential/common-mode chokes and power inductors. From core selection and gap grinding to multi-strand windings and isolated structures, our engineering covers the production pain points of flyback power transformers. If you are building 100W-class adapters, chargers or industrial supplies, talk to us early about magnetics manufacturability—the sooner the magnetics partner joins the design, the less rework before mass production.
For those doing flyback or DCM supply design: which step trips you up most—turns saturation, temperature rise, leakage, or safety creepage? Share in the comments.
Sources:
1. Design flow and formula framework from '100W DCM Flyback Transformer (ER28/34, 100kHz) Detailed Design', published by the WeChat account '磁性元件达人' (Magnetic Component Expert).
2. TDK PC95EER28-Z ferrite core datasheet (product.tdk.com, IEC 62317: Ae=82.1 mm², le=64 mm, Ve=5250 mm³, AL=4000 nH/N², Bs@100°C=410 mT).
3. TDK ferrite material chart (Mn-Zn Ferrite PC95): Pcv(100kHz, 200mT, 100°C)=280 kW/m³, Bs(100°C)=410 mT, Tc>215°C.
4. IEC 62368-1 AV/ICT safety standard: reinforced-insulation creepage (250 V, pollution 2, group IIIa) ≥6.4 mm.
All data are from public sources (vendor datasheets, industry standards, trade media); no unverified internal data used; customer names and order details omitted. Device numbers (FCP11N60, MBR20200CT, UC2844, etc.) are industry examples, not our products. Core loss extrapolated from official 200 mT to 228 mT by Steinmetz—order-of-magnitude estimate; verify by measurement before production.